These include overheating, running too long, power surges, and age. When the capacitor fails, the condenser fan will no longer rotate.
One of the main reasons a fan motor might malfunction is dirt inside the cabinet. … Like any motor, an air conditioner fan motor can become overheated if it works too hard and doesn’t receive proper maintenance. If your AC has worked for you most of the summer, the stress could cause the fan motors to burn out.
One of the most common reasons fans stop spinning is because of a dead capacitor. The AC’s capacitors are small, cylinder components that send energy signals to power the fan motor and the rest of the AC unit. … Capacitors can go bad over time and need to be replaced.
The average lifespan of an AC fan motor is about 12 years. An AC fan motor can last more than 12 years if it’s kept clean and cooled as needed. On the other hand, without annual maintenance checkups, your fan motor may only survive between one and three years.
When your air conditioner’s fan motor breaks, it will typically cost about $300 to $600 to replace. It’s imperative to get this fixed quickly, since without a working fan motor your air conditioner’s compressor can be the next domino to tumble. Its repair is even more significant — usually running closer to $2,000.
Every time you replace a condenser fan motor, you should also replace the A.C.’s run capacitor, which is a cylinder-shaped device that helps to start or run motors. To replace it, again take down all technical data on the unit, and note wiring colors and positions before removing it with a screw driver.
Screeching Sounds
If your air conditioner is making a shrieking noise, this is an indicator of an issue with the fan motor. This sound may also be caused by a broken motor in the compressor of the condenser system. A screeching or squealing noise may also be caused by a damaged blower fan motor inside your house.
The function of the AC compressor
An air conditioning unit can still appear to run with a malfunctioning HVAC compressor. AC unit is equipped with a pair of fans, which still can run even in case of a malfunctioned compressor.
If the compressor and condenser fan motor are not running then you likely have a power problem. If it is a heat pump check for a heat pump breaker trip and reset it. … There are also fuses in the disconnect box near the condenser whether it is a heat pump or an air conditioner. Check these fuses.
If the fan doesn’t start running, you may have a bad fan motor. If you have difficulty getting the blades to turn, there may be debris wrapped around the fan axle, or the motor bearings may be dirty or jammed.
The main causes of failure are loss of lubricant, a failed run capacitor, a failed bearing in a belt drive, a little water dripping into the windings or a voltage problem. So technicians should carefully check to find the cause of a failure before changing the motor.
This is around a 4 hour job by an experienced Tech. At home, by a Novice with decent skills, about 5 hours plus!
More likely is a lifespan of 10 to 20 years which means by the time the AC motor fails it’s often time to consider replacing the entire system. One reason they last so long is they are designed and manufactured to withstand extreme heat up to 140℉.
This could be because the circuit breaker has tripped or is off. Check your panel to confirm this. If the circuit breaker works fine, it could be a problem with loose wiring and connections. Your ceiling fan could also stop working due to internal defects namely shot ball bearings or an overheated motor.
Normally the condenser fan motor should be running when the compressor is running. Power ( 115 volts AC ) to the motor and it is not running is a bad fan motor.
The condenser fan (if it has a dedicated fan) or the radiator fan most always comes in (with AC on) when the compressor discharge pressure (or, alternatively, the liquid line one; look for where a sensor or a switch is located on the high pressure line) rises over an operative threshold.
Average Cost | High Cost | Low Cost |
---|---|---|
$170 | $400 | $120 |
In many cases, it’s caused by a bad belt or bearing in the blower motor. Unusually noisy motors inside air handlers and furnaces make squealing, screeching, rattling, and/or banging noises when the equipment malfunctions.
Unlike the condenser fan motor, the blower motor is located indoors. It’s the component that blows cool air through the ducts and into different parts of your home. … A single-speed motor can only operate at one speed, while a variable-speed motor can adjust its speed to produce different levels of airflow.
Condenser fan motors overheat when they reach a temperature of roughly 150 degrees Fahrenheit. Upon overheating, the motor will stop running, halting the HVAC system and potentially damaging other vital components.
1) Condenser Fan Motor
These motors are usually one speed and come in horsepower ranges from 1/6 hp to 1/3 hp. They always have a capacitor, usually a dual capacitor if it’s an original motor and a single capacitor if it’s a replacement aftermarket motor.
Although it is not too difficult to change a condenser fan motor, it is still possible to do it incorrectly. … Some condenser fan motors turn 1075 RPM while others turn around 850 RPM. They are not interchangeable. If you can’t read the label on the old motor, take it apart and look at the number of poles.
When the ac compressor not working but the fan is running, chances are the outer unit housing the compressor isn’t receiving power. … Other potential causes may include a faulty thermostat, mismatched indoor and outdoor units, or the AC may just be old.
Before AC compressors stop working altogether, they often display warning signs, like: Blowing warm air. Frequently tripping the circuit breaker. Shaking when the system is started.