In a situation where the motor doesn’t work on any speed, the most likely causes are: a blown power supply fuse, a bad motor ground connection, bad motor speed control module or a failed motor. On all systems, a failed blower motor is least likely.
Replacing a blower motor costs $450 on average with a typical range of $250 to $800. With a warranty, you might pay as little as $150 for labor alone. For high-end models, like those with large motors or access issues, you might pay as much as $2,000.
If the blower motor relay develops any sort of problem that hinders its ability to properly limit and distribute power, it may cause the blower motor fuse to blow. Any sort of electrical spikes or excessive current from a bad relay will blow the fuse and cut power in order to protect the system.
In the highest speed state, the blower resistor is bypassed completely and the fan is connected directly to the car’s battery, which allows maximum current through the motor. Power to the blower motor is fed through the blower motor resistor, so if it fails or has any issues power can be cut off to the motor.
You might also hear ongoing whirring noises, or noises that change or get louder if you increase the fan speed. These are all signs of problems with the blower motor. In some cases, you may even notice smoke or smells of burning while driving, in which case you should pull over immediately.
Weak airflow is a sign of blower motor failure. This part wears out eventually, meaning its fans can no longer push adequate amount of air out the vents or through window defrosters.
The blower motor needs routine lubrication, and often a specific kind of lubrication to upkeep performance and function over time. Otherwise, the fan might seize up and cause a loud noise (and an even louder repair bill). If you are knowledgeable of the process, you can add lubrication to the motor.
If you don’t want to sweat or shiver, then find a good mechanic. The replacement of the blower motor is common and straightforward, so most shops will perform the repair — many on the same day.
If your blower is constantly turning on/off when the furnace isn’t heating… …you most likely have a bad fan limit switch. … So if your furnace blower is turning on and off when the furnace isn’t in a heat cycle, it usually means the fan limit switch is defective.
Trent, one of the biggest reasons for blower motor resistors to have shorten life is actually because of faulty blower motor drawing too many amps, some times melting wires/plugs, heating up resistors shortening their life.
In a blower motor, the relay supplies the power that allows the fans to circulate warmed air. Essentially an on/off switch, the blower motor relay’s reactions start and end the heating process in HVAC systems by controlling the flow of current between the power source and the motor.
Set a digital multimeter for “ohms.” Set an ohms range that is equal to or higher than the value of the resistor to be tested. Touch the red lead from the meter to one side, and the black lead to the other. Resistors do not hold a polarity, so it doesn’t matter which side gets the red or black lead.
Your car’s blower motor is not only necessary for the operation of your air conditioner. Without a functioning blower motor your engine runs the risk of overheating. … Start car and see if blower motor works.
The fan switch may be at fault, but a more likely reason is that a blower motor resistor that controls the voltage going to the blower has packed it in, resulting in only one speed remaining operable – usually the highest speed. …
This may be due to a faulty heater blower motor or potentially a bad heater core. … Engine overheating can be caused by a number of things such as low coolant levels, a faulty thermostat, or a failing coolant fan switch.
Consider building sound insulation
If you are wondering how to quiet a noisy furnace blower, you should try adding sound insulation to the system. You can install a melamine foam next to the blower intake. Try securing the foam using steel wire so that the furnace blower does not suck it in.
If the motor has oil ports, it should be lubricated annually. Apply two or three drops of 10-weight nondetergent motor oil (not all-purpose oil) to each port. … If the blower shaft has oil ports, it, too, should be lubricated annually, following the same procedure.
Furnace Sounds Like a Jet Engine
If your furnace sounds like an airplane or jet engine taking off, it’s usually a gas issue. Gas could be leaking from a line or valve. Or, if you hear a click before the swooshing sound, you may have a broken heat exchanger that is leaking gas. … Gas leaks can become emergencies.
Almost every furnace has a reset button, which is typically located inside the blower housing next to the blower motor. … You should be able to locate the reset button by removing the access panel from the furnace blower motor housing and looking inside.
Your filter could be so saturated with dust and debris. … Every modern furnace is equipped with a safety shutoff that will be tripped if your furnace gets too hot, and a clogged air filter can cause your furnace to overheat, shut itself off and give you the illusion of a furnace not blowing air.
When your air conditioner’s fan motor breaks, it will typically cost about $300 to $600 to replace. It’s imperative to get this fixed quickly, since without a working fan motor your air conditioner’s compressor can be the next domino to tumble. Its repair is even more significant — usually running closer to $2,000.